Infrared photocell sensors is very excellent at work

2020-03-19

Infrared photocell sensors description:

Model:IR-20

Technology Parameter

Power supply :12/24V(AC/DC)

Max.Range up :20Meters(indoor or outdoor)

Opera temperature :-10℃+60℃

Max.TX working current :25mA

Max. RX working current :35mA

Max. Relay contact :Max 500mA e 48VAC/DC

IP rate :IP65

Meterial :ABS

Net Weight :160g

jutai Infrared Photocell Sensors

Installation

1. To open the IR-20, lift the front panel of the photocell.

2. Insert the cables in their housing and fix the base to the wall. If the photocell has to be mounted on a  wall, drill the three 5 ø holes and fit suitable screw anchors. If the photocell has to be mounted on  metal, drill the three 3 ø holes for fitting with the self_tapping screws.

3. Make the connections. Power the photocells with a voltage can be 12-24 VAC or 12-30 VDC. If  positioning, alignment and connection have been carried out properly, the red LED on the receiver will be off. Each time the ray is interrupted, the red LED switches on. 

4. Cover the photocell with the front panel. Insert to the stop and close it. Interrupt the ray several times checking the relay response. 

5. Fix the front panels with the provided screws.

Connection
jutai Infrared Photocell Sensors

 

Note:For one-to-one use: using AC and need to be shorted by the jump line hat.

Installation Diagram And Application
jutai Infrared Photocell Sensors

 

Size
 

 

jutai Infrared Photocell Sensors

 

 

 

 

 

 

 

 

Model:WIS-30

Technology Parameter

Power Supply Transmitter :2 x AA Alkaline Batteries, Only replace with alkaline batteries; do not use rechargeable batteries with this product.

Receiver :12-24VAC  12-24VDC

Max.Range up :30 Meters

Opera temperature :-20℃+60℃

Max.TX working current :<50uA

Max. RX working current :30mA @ 12V DC

Max. Relay contact :Max 500 mA e 48 Vac/dc

IP rate :IP65

Meterial :PC (UV) 

Net Weight :160g

Battery using life :≥ 2 years

jutai Infrared Photocell Sensors

 

Connection

jutai Infrared Photocell Sensors

 

Note : For safety used we suggest use Y capacitor connect to the COM contact and the power supply Earth.

Installation Diagram And Application

jutai Infrared Photocell Sensors
 

 

 

 

 

 

 

 

Size

jutai Infrared Photocell Sensors

 

Model:IS-30R

Technology Parameter

Power Supply Transmitter :2 x AA Alkaline Batteries, Only replace with alkaline batteries; do not use rechargeable batteries with this product.

Receiver :12 - 24V AC 12 - 30V DC

Rotation Angle :180 Degree

Receiver Power Consumption :30mA @ 12V DC

Transmitter Battery Life :Minimum 2 years

Battery Low Indication :Audible Beep

Specified Operating Distance :30m

Alignment :Automatic – 1m² @ 10m (circular area - assumes parallel surface)

Output Contact :Fail-safe, N/C and N/O, potential free contact

Output Contact :3A @ 30V DC Non-inductive

Operating Temperature :-20°C - +60°C

Operating Humidity :0 - 90° Non-condensing

Degree of Protection :Ip66

Housing Material :PC(UV)

Size :113*46.79*47.72mm

jutai Infrared Photocell Sensors

 

Installation 

1. Align the two holes in the case and lock two screws.

2. Put the battery inside(transmitter),thread the cable out(receiver).

3. Fix the screw.

4. Rotate the angle as required,and finally fix the bottom screw.

jutai Infrared Photocell Sensors

 

Gate Automation Application
jutai Infrared Photocell Sensors

 

Size
 

jutai Infrared Photocell Sensors

 

 

 

 

 

Model:IRR-7M

Technology Parameter

Sensing mode :Retro-reflective

Sensing distance :6M

Sensing object :Opaque object,min ψ75mm

Response time :≤3ms

Supply voltage :DC12-24V(10-30V DC)/ ripple(p-p): 10% max

Output type :NPN output

Output status :N.O.

Consumption :≤20mA

Load current :200mA

jutai Infrared Photocell Sensors

Technical parameter 

01. Voltage drop(V,):≤1.8V(200mA)

02. LED display:Red LED

03. Sensitivity adjustment:non-adjustable

04. Circuit Protection:Short circuit protection, reversed polarity protection and overload protection

05. Operating temperature:-10....+55

06. Insulation Resistance:≥50ΜΩ

07. Anti-impact:10...55Hz(amplitude 1.5mm)X,Y, Z direction, each 10times

08. Protection:Ip67

09. Connection:Cable: ψ4.8mm 2M

10. Housing material:PBT

11. Accessories:mounting bracket: 1pcs; Reflector: 1pcs

12. Product size:50*50*18cm

Infrared Photocell Sensors Applications

01. Logistics:Storage & Conveyor, especially pallet detection

02. Machine builders (e.g. packaging, handling, wood processing, paper)

03. Automotive

04. Automated car park systems

05. Doors and gates

06. Distribution

Infrared Photocell Sensors Size
jutai Infrared Photocell Sensors

 

 

jutai Infrared Photocell Sensors

I believe that customers use our products, we will be very satisfied with our quality and service! For more information, please refer to our website

 

jutai website

jutai website

More products information please contact me:

Juli Xu

Sales Specialist

Mobile: 0086-15778018527

Whatsapp: 0086-15778018527

Skype: Jili Xu

E-mail: jutaisales2@gmail.com

sales15@jutairfid.com

Facebook:Lizhu Xu

Wechat: JuliXu15

Share this Post:

Get in Touch with us

Fill out more information, We will get back to you within 24 hours.

Factory Address

5F,Mingjinhai Industrial Park, ShiyanTown, BaoAn,Shenzhen,China

Email

jutaigateaccess2@gmail.com

Contact Us

Telephone : 86-0755-29573855

Business Phone : 8613143400257

Work Time :8:00-18:00(Beijing time)

contact us