Jutai AC-44 Gate Access Software with Four Door Access Control Panel

Product Details
Brand JUTAI
Serial Number JTAC-44
Country of Origin China
Certificate CE/FCC
Payment & Shipping Terms
Price Quote Negotiate
Minimum Order 1 pcs
Average Delivery Time Sample order 3-4 days,normal order 5-10 days
Payment Method TT/Western Union,PayPal
Package Details 1 pcs per box
Ability to Supply 10000Pcs/month

JUTAI AC-44 With Four Relays Network Control Panel 

Four Door access control pannel working with Jutai gate access software to management door access people attantance. We will know who entrance time or exit time which door. Our gate access software can support 26,000 Users and 100,000 events memory.Four door access control panel have 4 pcs door entrance and 4 pcs door exit.Through TCP/IP connect to our company. Jutai gate access software have simple operation page and easy to learnning.

 

Door access control panel advantage

Built in web server:Built-in web server where network configuration such as IP address, subnet mask, server IP can be easily done upon; No more factory programming needed as the firmware can be upgraded via the on-board web server

Hign Performance:Based on the latest HCB (Hybrid Compact Board), is a high reliability, JUTAI AC-44 high efficiency and highly integrated intelligent multi-application control panel targeted for physical access control industry. this control panel can fulfill most demanding requirement in physical access control environment.

Door interlocking:In four doors interlocking within the control panel, no need external wire. Cross-board interlocking is achievable by checking the interlocking signal coming from second control panel before granting the accessibility to the local control panel.

Super network processor and combined with mass storage technology: Adopting super network processor and combined with mass storage technology, and which can achieve real network data exchange.

 

Four Relays Gate And Door Access Control System Network Control Panel used In Barrier Gate Access Control System Highlight

  • Support Single Door / 2 Doors/4 doors
  • Unlimited Access Level;
  • Support Car Park Mode;
  • Support Dynamic Reader Location;
  • Compatible with Various Reader Technologies;
  • Peer To Peer Global Anti-Passback;
  • Configurable Digital / Supervised Inputs (8)
  • Event Based Triggering (EBT)
  • Unlimited Access Level;
  • Onboard & Cross-Board Interlocking;
  • User Counting (Card Holder / Car Park)
  • Advance Encryption Standard (AES)
  • Reader Output Control
  • Support 26,000 Users And 100,000 Events Memory

 

Technical Specification Four Relays Gate And Door Access Control System Network Control Panel used In Barrier Gate Access Control System

  • Operating Temperature:-20 °C to 70°C
  • Card Holder: 26,000 users
  • Event Transaction: 100,000;
  • 4 groups 7A door lock relay output
  • 4 groups door sensor
  • 8 groups Wigand 26/34 interface;
  • 1 group RS485 interface
  • Additional alarm extension port ;
  • Supporting 4 groups alarm linkage (fire alarm, burglar alarm; gas alarm; door sensor)
  • Work voltage: DC9V to 14V;
  • Work current: <350mA;
  • Access Level: Unlimited Access Level;
  • Time zone:64 groups
  • Digital/Supervise Inputs for User configurable(Door Sensor/Request-To-Exit/Fire Input/General Purpose)
  • Digital Output: Max 4Dry contact Relay;
  • Network Communication Port: RJ-45 Self-Negotiate 10/100mbps;
  • Protection supporting: Power Protection/ Surge Protection;
  • Onboard LED Control: Power / Communication / LAN / Event / Error;
  • Data Base: Access or SQL
  • AC Fail Monitoring: Yes;
  • Backup Battery: Yes;

 

Wiring Connection Attention

  • JUTAI AC-44 ac power line: recommended to use the wire of 3 * 1.0 mm2 (or above), to prevent the leakage, the earth wire of power cord should be grounded.
  • Electric lock line: must use the wire of 2 * 1.0 mm2 (or above), routes line maximum length should not exceed 50 meters.
  • RS485 telecommunication line: recommended to use the wire of 3 * 0.5 mm2 (or above), recommended to use twisted-pair wire, routes line maximum length should not exceed 1200 meters, please add RS485 Repeaters to extend the communication distance if exceed the distance.
  • TCP/IP telecommunication line: please use the standard Internet cable, routes line maximum length should not exceed 100 meters.
  • Card reader line: recommended to use the wire of 8 * 0.5 mm2 (or above), routes line maximum length should not exceed 80 meters.
  • Door sensor or switch line: recommended to use the wire of 2 * 0.5 mm2 (or above), routes line maximum length should not exceed 100 meters.

 

Four Relays Gate And Door Access Control System Network Control Panel used In Barrier Gate Access Control System

JUTAI AC-44

 

Normally FAQ To Four Relays Gate And Door Access Control System Network Control Panel used In Barrier Gate Access Control System

Common functions and solutions

Common malfunctions

Access control / accessories

Reason

solutions

Access control board don’t work when power supply

Power light is not bright

“+” and “-” supply wire reversed

Connect line again

Measure Voltage is low

Power supply voltage is low

Change 12VDC  power supply

For Rs485 Connection between CPU and controller don’t work

Communication indicator RX light not bright

Choose wrong COM port

Choose correct COM port

Communication indicator RX light not bright

COM port is broken/or occupy

Change other COM port

Communication indicator RX light normally on

Rs485 “A” and ”B”line reversed

Correct line (A-A,B-B)

Communication instructions RX light flashing

The quantity of devices which connected with Rs485 is too much.

Reduce controller quantity , or add signal-amplifier

Communication indicator RX light flashing,not bright or normally on

Rs485 communication interface broken or don’t match

Using specified Rs485

Communication indicator RX light normally on or weak normally on

Controller power not connect ground wire

Connect ground wire

Computer leakage or Power leakage

Change leakage equipment and connect ground wire

External high-voltage electrical interference

Eliminate interference sources and connect ground wire

For TCP/TP Connection between CPU and controller don’t work

Rj45 port communication indicator light( orange) not bright

cable port not properly, Communication wire is wrong

Change communication wire and install

A hub port wrong

Change another hub port, or change new hub

Rj45 port communication indicator light( orange) bright

IP address have clash/ IP occupy by other equipment

Setting Access Controller IP same with Computer IP

Access Control  IP different in one network segment

Setting Access Controller IP same with Computer IP

Read card can’t open door

Access card indicator light , Read card is flashing

Invalid card,Illegal card

Please enroll the card

Expire time or not in valid time

Adjust card valid time

Reader WG0 and WG1 wire reversed

Connect reader and controller wire in correct

Reader wire is longer

Change short wire and new reader

Access card indicator light , Read card is normally on

Reader wire is wrong or reader broken

Check wire.change new reader

Access card indicator light normally on or weak normally on

the interference of card reader circuit is serious

Please replace the line and avoid interference sources (such as AC220 wires, motors, etc.)

Press the button is invalid

Access didn’t receive the signal of button

Circuit malfunction

Check the connection, connect the wire according to the right way.

Access had received the signal of button

The button had set the time interval

Reset the valid time interval

Door access electric plug locks, magnetic locks work abnormal

Door access work normal, but the lock does not work.

COM port of control board didn’t connect power + 12

COM port of control board connect power + 12, NO port connect positive pole of electric lock, electric lock negative pole connect power GND

Door access work normal, but the lock work with opposite operation

The NC port and NO port connected wrong

COM port of control board connect power + 12, NO port connect positive pole of electric lock, electric lock negative pole connect power GND

Door access work normal, but the lock powerless in work.

The voltage is too low or the electric lock line is too long

The work voltage should be in the scope in line with the requirement of the electric lock

Electric lock unlock time is too short or too long.

The adjusted lock delay time is not applicable.

 

Adjust the lock delay time with the management software.

 

Door access have alarm prompt, electric lock normally open all the time.

Have fire alarm or smoke alarm.

Please check the source of alarm, eliminate the alarm.

Door access is normal, but the electric lock normally open all the time.

 

Door access was set to normally open state.

 

Relieve the normally open state with the software, or long press the button for 5 seconds to close normally open or open normally open.

Electric control lock go wrong

High temperature or often burn electric control lock.

The unlock time extended.

Electric control lock unlock delay time set to 0.5 second.

High temperature or often burn electric control lock.

The line was connected wrong.

COM port of control board connect power + 12, NO port connect positive pole of electric lock, electric lock negative pole connect power GND

The expansion board of alarm is abnormal

The light of expansion board is not bright.

 

The control board and alarm extension board connected wrong

Please connect the control board and alarm extension board correctly

Extension board can't alarm

Circuit malfunction or alarm function is closed.

Check the input circuit and signal, check the alarm function whether effective.

Often have alarm prompt easily

 

Circuit connected wrong or parameter settings wrong.

Check alarm input line and check the alarm reason of controller property in the management system

 

JUTAI AC-44 display:

JUTAI AC-44

JUTAI AC-44

Get in Touch with us

Fill out more information, We will get back to you within 24 hours.

Factory Address

5F,Mingjinhai Industrial Park, ShiyanTown, BaoAn,Shenzhen,China

Email

jutaigateaccess2@gmail.com

Contact Us

Telephone : 86-0755-29573855

Business Phone : 8613143400257

Work Time :8:00-18:00(Beijing time)

contact us