The remote control operation of a barrier gate involves a solution that enables the control and management of the barrier gate device through remote technology. Our company has its own remote control solution, which we call Gatelink.
1. GateLink Remote System
JUTAI GateLink Automation Solution for Parking lot, an extension of residential smart gate solution, is an innovation of automatic sensing application for door’s opening and closing compared with the traditional long- distance card reader system. It’s principle is that the GATE remote control takes power through the car’s USB charging port. Within a sensing range of 30 meters, the remote receiving relay device will receive the signal and transmit USB ID to the access control device through the Weigand output. The USB ID numbers are saved in the CPU of the device in advance. The device will output a relay signal to the gate opening interface of the boom barrier’s control board when the ID is judged to be valid, and the barrier arm is up after receiving the signal. The barrier gate will automatically falls when the car passes over the anti-smashing ground sensing coil of the barrier.
2. Advantages of GateLink Remote
Simple usage: works with the receiver only by powering up the gatelink USB.
Anti-copy: the latest new chip encryption technology is adopted.
Good economic interest: distributors can encrypt the system and prevent from the copy of remote controls by the external devices.
Huge market potential: the system can be used in community access control, the residential access control with the GATELINK solution, wireless lighting control, and other expandable wireless application scenarios.
Convenience: Users can operate the barrier gate remotely without the need to be physically present. This provides greater flexibility and convenience, especially in situations where frequent opening and closing of the barrier gate are required.
Real-time Monitoring: Some remote control solutions provide real-time monitoring, allowing users to check the status of the barrier gate at any time. This enhances security by ensuring users are informed about the current situation on the premises.
Security: By implementing authentication and security measures, remote control solutions ensure that only authorized users can manipulate the barrier gate. This helps prevent unauthorized access and potential security risks.
Remote Management: Administrators can remotely monitor and manage multiple barrier gate devices without being physically present at each location. This increases efficiency in management and reduces time and operational costs.
Instant Response: Remote control devices can communicate with the barrier gate in real-time, resulting in faster response times. This is crucial in environments where quick responses to changing situations are essential, such as during peak hours in parking lots.
Energy Efficiency: Precise control over the opening and closing times of the barrier gate through remote control helps avoid unnecessary energy consumption. This contributes to energy conservation and aligns with environmental sustainability goals.
Customization and Scalability: Remote control solutions often offer high customization and scalability, allowing for tailored configurations and upgrades to meet specific needs and adapt to different scenarios and applications.
3. There are 4 solutions
Solution 1
Off-line Gatelink remote control application(no software required)
Working Procedure
❀ The car presses the loop coils at the entrance, triggering the work of the remote controls’ receiver to receive the USB ID number and send it to the AC868 access control device via Weigand.
❀ AC868 access control device receives the signal of remote(ID numbers are preserved in advance), and output a relay signal to the controller panel in the boom barrier when the ID is judged to be valid, and the barrier is open after receiving the signal. No signal with invalid ID.
❀ Boom barrier arm is up when the controller panel receives the signal by AC866 access control device.
❀ Boom barrier arm falls when the car passes over the loop detector coil.
❀ Off-line application doesn’t support local internet and record checking by software.
Solution 2
GateLink remote control of local system application; (with PC software) #Smart Community Parking
Working Procedure
❀ The car presses the loop coils at entrance, triggering the work of the remote controls’ receiver to receive the USB ID number and send it to the AC-11 access controller panel via Weigand.
❀ AC-11 access controller panel receives the signal of remote(ID numbers are preserved in advance), and output a relay signal to the controller panel in the boom barrier when the ID is judged to be valid, and the barrier is open after receiving the signal. No signal with invalid ID.
❀ Boom barrier arm is up when the controller panel receives the signal byAC-11 access controller panel.
❀ Boom barrier arm falls when the car passes over the loop detector coil.
❀ The access records in the controller panel will be transmitted to the PC software via TCP/IP.
❀ This solution is belong to internet usage, supports local internet and can check access records via software.
Solution 3
GateLink remote control application based on the cloud system
4. Hardware Equipment Parameters
❀ USB gatelink
❀ USB Transmitter
❀ Remote Control Relay (Door Lock)
❀ 866 Access Control Device
❀ AC-11 Access Controller Panel
❀ 4G Panel
❀ LD-100 Vehicle Loop Detector
❀ BR-100 Automatic boom barrier
❀ JTHT-11 Loop Detector Coil
All in all, this type of solution finds applications in various areas, including parking lots, residential gate access, and corporate entrances, where remote control and management are necessary. Ensure that security and reliability are taken into account when implementing a remote control solution to prevent unauthorized access or system failures. #Smart Community Parking
Fill out more information, We will get back to you within 24 hours.
5F,Mingjinhai Industrial Park, ShiyanTown, BaoAn,Shenzhen,China
jutaigateaccess2@gmail.com
Telephone : 86-0755-29573855
Business Phone : 8613143400257